General introduction
AXG magnetic flow meter is ideal for industrial process lines like oil & gas, chemical, pulp & paper, food & beverage, or metal & mining applications. With outstanding reliability and ease of operation and maintenance, developed on decades of field-proven experience, the AXG will increase user benefits while reducing total cost of ownership. The sizes are available from 2.5 to 500 mm (0.1 to20 in.). For lining, fluorocarbon PFA lining or ceramics tube which can be applied to severe applications can be selected. Process connection also supports various specifications such as ASME, EN, AS, and JIS.
Besides, AXG magnetic flow meter come with several outstanding features as: dual frequency excitation method realizes stable measurement; maximum four inputs/outputs of current, pulse, andstatus signals can be selected; improved operation and monitoring function, improved Maintainability variable Communication Protocol as Hart 7, Brain and Modbus. It's available for both integrate and remote type, transmitter AXG4A and AXF11AG are selectable for remote construction type.
Main Specifications
Meter size
|
Accuracy
|
Measure Range
|
Lining
|
Electrode
|
Process Connection
|
2.5 to 500mm
|
Standard: ± 0.3%
High accuracy: ± 0.15% (25 to 200mm)
|
0.1 to 10m/s
|
PFA: 25 to 500mm
Ceramic: 2.5 to 200mm
|
Stainless steel 316L, Nickel alloy, Platinum-Iridium, Tantalum, Titanium, Tungsten carbide, Platinum-Alumina cermet
|
Wafer, Flange, Union Joint, Welding
|
Model selection of General-purpose, Submersible, Explosion protection, Wafer, Flange, PFA Lining (2.5 to 400 mm/0.1 to 16 in.)
Model
|
Suffix Codes
|
Description
|
AXG002
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (2.5 mm/0.1 in)
|
AXG005
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (5 mm/0.2 in)
|
AXG010
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (10 mm/0.4 in)
|
AXG015
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (15 mm/0.5 in)
|
AXG025
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (25 mm/1 in)
|
AXG032
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (32 mm/1.25 in)
|
AXG040
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (40 mm/1.5 in)
|
AXG050
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (50 mm/2 in)
|
AXG065
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (65 mm/2.5 in)
|
AXG080
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (80 mm/3 in)
|
AXG100
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (100 mm/4 in)
|
AXG125
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (125 mm/5 in)
|
AXG150
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (150 mm/6 in)
|
AXG200
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (200 mm/8 in)
|
AXG250
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (250 mm/10 in)
|
AXG300
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (300 mm/12 in)
|
AXG350
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (350 mm/14 in)
|
AXG400
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (400 mm/16 in)
|
Use
|
-G
|
|
|
|
|
|
|
|
|
|
|
|
|
|
General-purpose
|
-C
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Explosion protection
|
-W
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Submersible
|
Construction
|
|
A
|
|
|
|
|
|
|
|
|
|
|
|
|
Integral Flowmeter
|
|
D
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Sensor (for AXFA11)
|
|
G
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Sensor (for AXG4A)
|
Explosion Protection
|
|
|
000
|
|
|
|
|
|
|
|
|
|
|
|
Non Explosion Protection Approval
|
|
|
KF2
|
|
|
|
|
|
|
|
|
|
|
|
ATEX Flameproof
|
|
|
SF2
|
|
|
|
|
|
|
|
|
|
|
|
IECEx Flameproof
|
|
|
JF5
|
|
|
|
|
|
|
|
|
|
|
|
Japan Flameproof
|
Process Connection(Wafer)
|
|
|
|
AA1
|
|
|
|
|
|
|
|
|
|
|
ASME Class 150 Wafer
|
|
|
|
AA2
|
|
|
|
|
|
|
|
|
|
|
ASME Class 300 Wafer
|
|
|
|
AE1
|
|
|
|
|
|
|
|
|
|
|
EN PN10 Wafer
|
|
|
|
AE2
|
|
|
|
|
|
|
|
|
|
|
EN PN16 Wafer
|
|
|
|
AE4
|
|
|
|
|
|
|
|
|
|
|
EN PN40 Wafer
|
|
|
|
AG1
|
|
|
|
|
|
|
|
|
|
|
JIS F12 Wafer
|
|
|
|
AJ1
|
|
|
|
|
|
|
|
|
|
|
JIS 10K Wafer
|
|
|
|
AJ2
|
|
|
|
|
|
|
|
|
|
|
JIS 20K Wafer
|
|
|
|
AP1
|
|
|
|
|
|
|
|
|
|
|
JPI Class 150 Wafer
|
Process Connection (Flange F304)
|
|
|
|
BA1
|
|
|
|
|
|
|
|
|
|
|
ASME Class 150 Flange
|
|
|
|
BA2
|
|
|
|
|
|
|
|
|
|
|
ASME Class 300 Flange
|
|
|
|
BE1
|
|
|
|
|
|
|
|
|
|
|
EN PN10 Flange
|
|
|
|
BE2
|
|
|
|
|
|
|
|
|
|
|
EN PN16 Flange
|
|
|
|
BE4
|
|
|
|
|
|
|
|
|
|
|
EN PN40 Flange
|
|
|
|
BG1
|
|
|
|
|
|
|
|
|
|
|
JIS F12 Flange
|
|
|
|
BJ1
|
|
|
|
|
|
|
|
|
|
|
JIS 10K Flange
|
|
|
|
BJ2
|
|
|
|
|
|
|
|
|
|
|
JIS 20K Flange
|
|
|
|
BP1
|
|
|
|
|
|
|
|
|
|
|
JPI Class 150 Flange
|
|
|
|
DE4
|
|
|
|
|
|
|
|
|
|
|
EN PN40 Flange (Nominal Diameter 10 mm)
|
|
|
|
DJ1
|
|
|
|
|
|
|
|
|
|
|
JIS 10K Flange (Nominal Diameter 10 mm)
|
|
|
|
DJ2
|
|
|
|
|
|
|
|
|
|
|
JIS 20K Flange (Nominal Diameter 10 mm)
|
Process Connection (Flange F316)
|
|
|
|
PA1
|
|
|
|
|
|
|
|
|
|
|
ASME Class 150 Flange
|
|
|
|
PA2
|
|
|
|
|
|
|
|
|
|
|
ASME Class 300 Flange
|
|
|
|
PE1
|
|
|
|
|
|
|
|
|
|
|
EN PN10 Flange
|
|
|
|
PE2
|
|
|
|
|
|
|
|
|
|
|
EN PN16 Flange
|
|
|
|
PE4
|
|
|
|
|
|
|
|
|
|
|
EN PN40 Flange
|
|
|
|
PJ1
|
|
|
|
|
|
|
|
|
|
|
JIS 10K Flange
|
Process Connection (Flange CS)
|
|
|
|
CA1
|
|
|
|
|
|
|
|
|
|
|
ASME Class 150 Flange
|
|
|
|
CA2
|
|
|
|
|
|
|
|
|
|
|
ASME Class 300 Flange
|
|
|
|
CE1
|
|
|
|
|
|
|
|
|
|
|
EN PN10 Flange
|
|
|
|
CE2
|
|
|
|
|
|
|
|
|
|
|
EN PN16 Flange
|
|
|
|
CE4
|
|
|
|
|
|
|
|
|
|
|
EN PN40 Flange
|
|
|
|
CG1
|
|
|
|
|
|
|
|
|
|
|
JIS F12 Flange
|
|
|
|
CJ1
|
|
|
|
|
|
|
|
|
|
|
JIS 10K Flange
|
|
|
|
CJ2
|
|
|
|
|
|
|
|
|
|
|
JIS 20K Flange
|
|
|
|
CS1
|
|
|
|
|
|
|
|
|
|
|
AS Table D Flange
|
|
|
|
CS2
|
|
|
|
|
|
|
|
|
|
|
AS Table E Flange
|
Lining
|
|
|
|
|
A
|
|
|
|
|
|
|
|
|
|
PFA Lining
|
Electrode
|
|
|
|
|
|
L
|
|
|
|
|
|
|
|
|
Stainless Steel 316L
|
|
|
|
|
|
P
|
|
|
|
|
|
|
|
|
Platinum-Iridium
|
|
|
|
|
|
H
|
|
|
|
|
|
|
|
|
Nickel Alloy
|
|
|
|
|
|
T
|
|
|
|
|
|
|
|
|
Tantalum
|
|
|
|
|
|
V
|
|
|
|
|
|
|
|
|
Titanium
|
|
|
|
|
|
W
|
|
|
|
|
|
|
|
|
Tungsten Carbide
|
Grounding Device
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
|
None
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
|
Grounding Rings
|
|
|
|
|
|
|
3
|
|
|
|
|
|
|
|
Built-in Grounding Electrodes
|
Housing and Coating
|
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
Standard Material with Standard Coating
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
Standard Material with Rugged Coating
|
Cable Entry
|
|
|
|
|
|
|
|
|
0
|
|
|
|
|
|
JIS G1/2 Female
|
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
ASME 1/2 NPT Female
|
|
|
|
|
|
|
|
|
4
|
|
|
|
|
|
ISO M20×1.5 Female
|
Accuracy
|
|
|
|
|
|
|
|
|
|
B
|
|
|
|
|
Standard
|
|
|
|
|
|
|
|
|
|
C
|
|
|
|
|
High Grade
|
Power Supply
|
|
|
|
|
|
|
|
|
|
|
-1
|
|
|
|
100-240 V AC / 100-120 V DC
|
|
|
|
|
|
|
|
|
|
|
-2
|
|
|
|
24 V AC / DC
|
|
|
|
|
|
|
|
|
|
|
-N
|
|
|
|
None (Remote Sensor)
|
Communication and I/O
|
|
|
|
|
|
|
|
|
|
|
|
D#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, BRAIN and I/O
|
|
|
|
|
|
|
|
|
|
|
|
J#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, HART 7 and I/O
|
|
|
|
|
|
|
|
|
|
|
|
M#
|
|
|
#: 0, 2, 6, Modbus and I/O
|
|
|
|
|
|
|
|
|
|
|
|
NN
|
|
|
None (Remote Sensor)
|
Transmitter Wiring Terminal
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
|
M4 Screw-type
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
|
Clamp Type
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
|
None (Remote Sensor)
|
Display
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
With Display (English, Multi-language)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
With Display (English, Chinese)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
Without Display/Remote Sensor
|
Optional codes
|
/Optional codes
|
4. Model selection of General-purpose, Submersible, Flange, PFA Lining (500 mm/20 in.)
Model
|
Suffix Codes
|
Description
|
AXG500
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (500 mm/20 in)
|
Use
|
-G
|
|
|
|
|
|
|
|
|
|
|
|
|
|
General-purpose
|
-W
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Submersible
|
Construction
|
|
D
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Sensor (for AXFA11)
|
Explosion Protection
|
|
|
000
|
|
|
|
|
|
|
|
|
|
|
|
Non Explosion Protection Approval
|
Process Connection (Flange F304)
|
|
|
|
BA1
|
|
|
|
|
|
|
|
|
|
|
ASME Class 150 Flange
|
|
|
|
BE1
|
|
|
|
|
|
|
|
|
|
|
EN PN10 Flange
|
|
|
|
BE2
|
|
|
|
|
|
|
|
|
|
|
EN PN16 Flange
|
Process Connection (Flange CS)
|
|
|
|
CA1
|
|
|
|
|
|
|
|
|
|
|
ASME Class 150 Flange
|
|
|
|
CE1
|
|
|
|
|
|
|
|
|
|
|
EN PN10 Flange
|
|
|
|
CE2
|
|
|
|
|
|
|
|
|
|
|
EN PN16 Flange
|
Lining
|
|
|
|
|
A
|
|
|
|
|
|
|
|
|
|
PFA Lining
|
Electrode
|
|
|
|
|
|
L
|
|
|
|
|
|
|
|
|
Stainless Steel 316L
|
|
|
|
|
|
H
|
|
|
|
|
|
|
|
|
Nickel Alloy
|
Grounding Device
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
|
None
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
|
Grounding Rings
|
Housing and Coating
|
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
Standard Material with Standard Coating
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
Standard Material with Rugged Coating
|
Cable Entry
|
|
|
|
|
|
|
|
|
0
|
|
|
|
|
|
JIS G1/2 Female
|
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
ASME 1/2 NPT Female
|
|
|
|
|
|
|
|
|
4
|
|
|
|
|
|
ISO M20×1.5 Female
|
Accuracy
|
|
|
|
|
|
|
|
|
|
B
|
|
|
|
|
Standard
|
Power Supply
|
|
|
|
|
|
|
|
|
|
|
-N
|
|
|
|
None (Remote Sensor)
|
Communication and I/O
|
|
|
|
|
|
|
|
|
|
|
|
NN
|
|
|
None (Remote Sensor)
|
Transmitter Wiring Terminal
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
|
None (Remote Sensor)
|
Display
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
Without Display/Remote Sensor
|
Optional codes
|
/Optional codes
|
Model selection of General-purpose, Submersible, Explosionprotection, Flange, PFA Lining (High Pressure Type, ASME Class 600)
Model
|
Suffix Codes
|
Description
|
AXG025
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (25 mm/1 in)
|
AXG040
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (40 mm/1.5 in)
|
AXG050
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (50 mm/2 in)
|
AXG080
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (80 mm/3 in)
|
AXG100
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (100 mm/4 in)
|
Use
|
-G
|
|
|
|
|
|
|
|
|
|
|
|
|
|
General-purpose
|
-C
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Explosion protection
|
-W
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Submersible
|
Construction
|
|
A
|
|
|
|
|
|
|
|
|
|
|
|
|
Integral Flowmeter
|
|
D
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Sensor (for AXFA11)
|
|
G
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Sensor (for AXG4A)
|
Explosion Protection
|
|
|
000
|
|
|
|
|
|
|
|
|
|
|
|
Non Explosion Protection Approval
|
|
|
SF2
|
|
|
|
|
|
|
|
|
|
|
|
IECEx Flameproof
|
Process Connection (Flange F304)
|
|
|
|
EA4
|
|
|
|
|
|
|
|
|
|
|
ASME Class 600 Flange (High Pressure)
|
Lining
|
|
|
|
|
A
|
|
|
|
|
|
|
|
|
|
PFA Lining
|
Electrode
|
|
|
|
|
|
L
|
|
|
|
|
|
|
|
|
Stainless Steel 316L
|
Grounding device
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
|
Grounding Rings
|
Housing and Coating
|
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
Standard Material with Standard Coating
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
Standard Material with Rugged Coating
|
Cable Entry
|
|
|
|
|
|
|
|
|
0
|
|
|
|
|
|
JIS G1/2 Female
|
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
ASME 1/2 NPT Female
|
|
|
|
|
|
|
|
|
4
|
|
|
|
|
|
ISO M20×1.5 Female
|
Accuracy
|
|
|
|
|
|
|
|
|
|
B
|
|
|
|
|
Standard
|
Power Supply
|
|
|
|
|
|
|
|
|
|
|
-1
|
|
|
|
100-240 V AC / 100-120 V DC
|
|
|
|
|
|
|
|
|
|
|
-2
|
|
|
|
24 V AC / DC
|
|
|
|
|
|
|
|
|
|
|
-N
|
|
|
|
None (Remote Sensor)
|
Communication and I/O
|
|
|
|
|
|
|
|
|
|
|
|
D#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, BRAIN and I/O
|
|
|
|
|
|
|
|
|
|
|
|
J#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, HART 7 and I/O
|
|
|
|
|
|
|
|
|
|
|
|
M#
|
|
|
#: 0, 2, 6, Modbus and I/O
|
|
|
|
|
|
|
|
|
|
|
|
NN
|
|
|
None (Remote Sensor)
|
Transmitter Wiring Terminal
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
|
M4 Screw-type
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
|
Clamp Type
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
|
None (Remote Sensor)
|
Display
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
With Display (English, Multi-language)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
With Display (English, Chinese)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
Without Display/Remote Sensor
|
Optional codes
|
/Optional codes
|
Model selection of General-purpose, Explosionprotection, Ceramics Tube
Model
|
Suffix Codes
|
Description
|
AXG002
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (2.5 mm/0.1 in)
|
AXG005
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (5 mm/0.2 in)
|
AXG010
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (10 mm/0.4 in)
|
AXG015
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (15 mm/0.5 in)
|
AXG025
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (25 mm/1 in)
|
AXG040
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (40 mm/1.5 in)
|
AXG050
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (50 mm/2 in)
|
AXG080
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (80 mm/3 in)
|
AXG100
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (100 mm/4 in)
|
AXG150
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (150 mm/6 in)
|
AXG200
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (200 mm/8 in)
|
Use
|
-G
|
|
|
|
|
|
|
|
|
|
|
|
|
|
General-purpose
|
-C
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Explosion protection
|
Construction
|
|
A
|
|
|
|
|
|
|
|
|
|
|
|
|
Integral Flowmeter
|
|
D
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Sensor (for AXFA11)
|
|
G
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Sensor (for AXG4A)
|
Explosion Protection
|
|
|
000
|
|
|
|
|
|
|
|
|
|
|
|
Non Explosion Protection Approval
|
|
|
KF2
|
|
|
|
|
|
|
|
|
|
|
|
ATEX Flameproof
|
|
|
SF2
|
|
|
|
|
|
|
|
|
|
|
|
IECEx Flameproof
|
|
|
JF5
|
|
|
|
|
|
|
|
|
|
|
|
Japan Flameproof
|
Process Connection(Wafer)
|
|
|
|
AA1
|
|
|
|
|
|
|
|
|
|
|
ASME Class 150 Wafer
|
|
|
|
AA2
|
|
|
|
|
|
|
|
|
|
|
ASME Class 300 Wafer
|
|
|
|
AE1
|
|
|
|
|
|
|
|
|
|
|
EN PN10 Wafer
|
|
|
|
AE2
|
|
|
|
|
|
|
|
|
|
|
EN PN16 Wafer
|
|
|
|
AE4
|
|
|
|
|
|
|
|
|
|
|
EN PN40 Wafer
|
|
|
|
AG1
|
|
|
|
|
|
|
|
|
|
|
JIS F12 Wafer
|
|
|
|
AJ1
|
|
|
|
|
|
|
|
|
|
|
JIS 10K Wafer
|
|
|
|
AJ2
|
|
|
|
|
|
|
|
|
|
|
JIS 20K Wafer
|
Process Connection (Union Joint F316)
|
|
|
|
GUN
|
|
|
|
|
|
|
|
|
|
|
Screw Union Joint
|
|
|
|
GUR
|
|
|
|
|
|
|
|
|
|
|
Screw Union Joint
|
|
|
|
GUW
|
|
|
|
|
|
|
|
|
|
|
Welding Union Joint
|
Lining
|
|
|
|
|
C
|
|
|
|
|
|
|
|
|
|
Ceramics Tube
|
Electrode
|
|
|
|
|
|
E
|
|
|
|
|
|
|
|
|
Platinum-alumina Cermet
|
Grounding Device
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
|
None
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
|
Grounding Rings
|
Housing and Coating
|
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
Standard Material with Standard Coating
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
Standard Material with Rugged Coating
|
Cable Entry
|
|
|
|
|
|
|
|
|
0
|
|
|
|
|
|
JIS G1/2 Female
|
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
ASME 1/2 NPT Female
|
|
|
|
|
|
|
|
|
4
|
|
|
|
|
|
ISO M20×1.5 Female
|
Accuracy
|
|
|
|
|
|
|
|
|
|
B
|
|
|
|
|
Standard
|
|
|
|
|
|
|
|
|
|
C
|
|
|
|
|
High Grade
|
Power Supply
|
|
|
|
|
|
|
|
|
|
|
-1
|
|
|
|
100-240 V AC / 100-120 V DC
|
|
|
|
|
|
|
|
|
|
|
-2
|
|
|
|
24 V AC / DC
|
|
|
|
|
|
|
|
|
|
|
-N
|
|
|
|
None (Remote Sensor)
|
Communication and I/O
|
|
|
|
|
|
|
|
|
|
|
|
D#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, BRAIN and I/O
|
|
|
|
|
|
|
|
|
|
|
|
J#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, HART 7 and I/O
|
|
|
|
|
|
|
|
|
|
|
|
M#
|
|
|
#: 0, 2, 6, Modbus and I/O
|
|
|
|
|
|
|
|
|
|
|
|
NN
|
|
|
None (Remote Sensor)
|
Transmitter Wiring Terminal
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
|
M4 Screw-type
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
|
Clamp Type
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
|
None (Remote Sensor)
|
Display
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
With Display (English, Multi-language)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
With Display (English, Chinese)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
Without Display/Remote Sensor
|
Optional codes
|
/Optional codes
|
Model selection of Hygienic, Hygienic Explosion protection, PFA Lining
Model
|
Suffix Codes
|
Description
|
AXG015
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (15 mm/0.5 in)
|
AXG025
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (25 mm/1 in)
|
AXG032
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (32 mm/1.25 in)
|
AXG040
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (40 mm/1.5 in)
|
AXG050
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (50 mm/2 in)
|
AXG065
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (65 mm/2.5 in)
|
AXG080
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (80 mm/3 in)
|
AXG100
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (100 mm/4 in)
|
AXG125
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter (125 mm/5 in)
|
Use
|
-H
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Hygienic
|
-J
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Hygienic Explosion Protection
|
Construction
|
|
A
|
|
|
|
|
|
|
|
|
|
|
|
|
Integral Flowmeter
|
|
D
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Sensor (for AXFA11)
|
|
G
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Sensor (for AXG4A)
|
Explosion Protection
|
|
|
000
|
|
|
|
|
|
|
|
|
|
|
|
Non Explosion Protection Approval
|
|
|
KF2
|
|
|
|
|
|
|
|
|
|
|
|
ATEX Flameproof
|
|
|
SF2
|
|
|
|
|
|
|
|
|
|
|
|
IECEx Flameproof
|
|
|
JF5
|
|
|
|
|
|
|
|
|
|
|
|
Japan Flameproof
|
Process Connection(Clamp)
|
|
|
|
HAB
|
|
|
|
|
|
|
|
|
|
|
Tri-Clamp, Stainless Steel F316L
|
|
|
|
HDB
|
|
|
|
|
|
|
|
|
|
|
DIN 32676 Clamp, Stainless Steel F316L
|
|
|
|
HJA
|
|
|
|
|
|
|
|
|
|
|
ISO 2852 Clamp (for JIS G3447 Piping), Stainless Steel F304
|
|
|
|
HJB
|
|
|
|
|
|
|
|
|
|
|
ISO 2852 Clamp (for JIS G3447 Piping), Stainless Steel F316L
|
|
|
|
HKB
|
|
|
|
|
|
|
|
|
|
|
ISO 2852 / SMS 3016 Clamp, Stainless Steel F316L
|
Process Connection (Union)
|
|
|
|
JDB
|
|
|
|
|
|
|
|
|
|
|
DIN 11851 Union, Stainless Steel F316L
|
|
|
|
JJA
|
|
|
|
|
|
|
|
|
|
|
ISO 2853 Union (for JIS G3447 Piping), Stainless Steel F304
|
|
|
|
JJB
|
|
|
|
|
|
|
|
|
|
|
ISO 2853 Union (for JIS G3447 Piping), Stainless Steel F316L
|
|
|
|
JKB
|
|
|
|
|
|
|
|
|
|
|
ISO 2853 Union, Stainless Steel F316L
|
|
|
|
JSB
|
|
|
|
|
|
|
|
|
|
|
SMS 1145 Union (Open groove packing type), Stainless Steel F316L
|
Process Connection (Butt Weld Joint)
|
|
|
|
KDB
|
|
|
|
|
|
|
|
|
|
|
DIN 11850 Piping Butt Weld Joint, Stainless Steel F316L
|
|
|
|
KJA
|
|
|
|
|
|
|
|
|
|
|
JIS G3447 Piping Butt Weld Joint, Stainless Steel F304
|
|
|
|
KJB
|
|
|
|
|
|
|
|
|
|
|
JIS G3447 Piping Butt Weld Joint, Stainless Steel F316L
|
|
|
|
KKB
|
|
|
|
|
|
|
|
|
|
|
ISO 2037 Piping Butt Weld Joint, Stainless Steel F316L
|
Lining
|
|
|
|
|
A
|
|
|
|
|
|
|
|
|
|
PFA Lining
|
Electrode
|
|
|
|
|
|
L
|
|
|
|
|
|
|
|
|
Stainless Steel 316L
|
Grounding Device
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
|
None
|
Housing and Coating
|
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
Standard Material with Standard Coating
|
Cable Entry
|
|
|
|
|
|
|
|
|
0
|
|
|
|
|
|
JIS G1/2 Female
|
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
ASME 1/2 NPT Female
|
|
|
|
|
|
|
|
|
4
|
|
|
|
|
|
ISO M20×1.5 Female
|
Accuracy
|
|
|
|
|
|
|
|
|
|
B
|
|
|
|
|
Standard
|
|
|
|
|
|
|
|
|
|
C
|
|
|
|
|
High Grade
|
Power Supply
|
|
|
|
|
|
|
|
|
|
|
-1
|
|
|
|
100-240 V AC / 100-120 V DC
|
|
|
|
|
|
|
|
|
|
|
-2
|
|
|
|
24 V AC / DC
|
|
|
|
|
|
|
|
|
|
|
-N
|
|
|
|
None (Remote Sensor)
|
Communication and I/O
|
|
|
|
|
|
|
|
|
|
|
|
D#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, BRAIN and I/O
|
|
|
|
|
|
|
|
|
|
|
|
J#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, HART 7 and I/O
|
|
|
|
|
|
|
|
|
|
|
|
M#
|
|
|
#: 0, 2, 6, Modbus and I/O
|
|
|
|
|
|
|
|
|
|
|
|
NN
|
|
|
None (Remote Sensor)
|
Transmitter Wiring Terminal
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
|
M4 Screw-type
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
|
Clamp Type
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
|
None (Remote Sensor)
|
Display
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
With Display (English, Multi-language)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
With Display (English, Chinese)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N
|
Without Display/Remote Sensor
|
Optional codes
|
/Optional codes
|
8. Model selection of General-purpose, Explosion protection. Remote Transmitter
Model
|
Suffix Codes
|
Description
|
AXG4A
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter Remote Transmitter
|
Use
|
-G
|
|
|
|
|
|
|
|
General-purpose
|
-C
|
|
|
|
|
|
|
|
Explosion Protection
|
Explosion Protection
|
|
000
|
|
|
|
|
|
|
Non Explosion Protection Approval
|
|
KF2
|
|
|
|
|
|
|
ATEX Flameproof
|
|
SF2
|
|
|
|
|
|
|
IECEx Flameproof
|
|
JF5
|
|
|
|
|
|
|
Japan Flameproof
|
Housing and Coating
|
|
|
1
|
|
|
|
|
|
Standard Material with Standard Coating
|
|
|
2
|
|
|
|
|
|
Standard Material with Rugged Coating
|
Cable Entry
|
|
|
|
0
|
|
|
|
|
JIS G1/2 Female
|
|
|
|
2
|
|
|
|
|
ASME 1/2 NPT Female
|
|
|
|
4
|
|
|
|
|
ISO M20×1.5 Female
|
Power Supply
|
|
|
|
|
1
|
|
|
|
100-240 V AC / 100-120 V DC
|
|
|
|
|
2
|
|
|
|
24 V AC / DC
|
Communication and I/O
|
|
|
|
|
|
D#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, BRAIN and I/O
|
|
|
|
|
|
J#
|
|
|
#: A, B, C, D, E, F, G, H, J, K, HART 7 and I/O
|
|
|
|
|
|
M#
|
|
|
#: 0, 2, 6, Modbus and I/O
|
|
|
|
|
|
NN
|
|
|
None (Remote Sensor)
|
Transmitter Wiring Terminal
|
|
|
|
|
|
|
1
|
|
M4 Screw-type
|
|
|
|
|
|
|
2
|
|
Clamp Type
|
Display
|
|
|
|
|
|
|
|
1
|
With Display (English, Multi-language)
|
|
|
|
|
|
|
|
2
|
With Display (English, Chinese)
|
|
|
|
|
|
|
|
N
|
Without Display/Remote Sensor
|
Optional codes
|
/Optional codes
|
Model selection of Signal Cable for Remote Transmitter
Model
|
Suffix Codes
|
Description
|
AX01C
|
|
|
|
|
|
|
|
|
Magnetic Flowmeter Signal Cable
|
Cable Finish and
Length
|
--A###
|
|
|
|
|
|
|
|
Unfinished, Cable length ### m, Set of Finishing Parts for M4 Screws
|
-C###
|
|
|
|
|
|
|
|
Finished for AXG4A, Cable Length ### m
|
-D###
|
|
|
|
|
|
|
|
Finished for AXFA11, Cable Length ### m
|
Finishing Parts
|
|
/C#
|
|
|
|
|
|
|
Finishing Parts (# sets)
|